Descriere
- To monitor 1 … 4 safety edge(s)
- 1 safety contact, STOP 0
- 1 Signalling output
| Ambient temperature, maximum | 55 |
|---|---|
| Ambient temperature, minimum | 5 |
| Automatic reset function | Yes |
| Basic quantity unit | Piece |
| Cable section, maximum | 2 x 1.5 mm² |
| Certificates | TÜV; EAC |
| Climatic stress | EN ISO 13856-2 |
| Control category to EN13849 | 3 |
| Control category to EN954 | 3 |
| Degree of pollution to VDE 0110 | 2 |
| EAN ( European Article Number) | 4030661293622 |
| EAN (European Article Number) | 4030661293622 |
| EMC rating | EMC-Directive |
| Earth connection detection | Yes |
| Electrical power consumption, maximum | 4 |
| Electronic Fuse | Yes |
| Enclosure material | Glass-fibre, thermoplastic |
| Feedback circuit | Yes |
| Frequency range | 50 |
| Gross weight | 175.000 |
| Height | 100 |
| Indicated operating states | Authorised operation; fault indication |
| Integral System Diagnostics, status | Yes |
| Length of cable | 200 |
| Mechanical life, minimum | 10000000 |
| Mission Time | 20 |
| Mounting | Snaps onto standard DIN rail to EN 60715 |
| Net weight | 175.000 |
| Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
| Note (General) | The overall machine safety depends on the professional mounting and installation of the safety monitoring module and the signal transmitter, as well as on the correct and professional electrical connection of the components.; If there it any risk whatsoever, the machine may not be restarted. |
| Note (PFH-value) | up to max. 5,000 switching cycles/year |
| Note (Wiring diagram) | Both re-initialisation and auto-reset must comply with the requirements of EN 1760-2 (diagram A2, A3).; The wiring diagram is shown for the de-energised condition.; Monitoring the safety edges SE 40 / SE 70 with a safety monitoring unit SE-304C up to PL d and Category 3.; Manual reset function or auto-reset: the manual reset function is triggered by an edge-sensitive signal (edge switching "0-1-0" within 100 ms up to 2 s) (X2/X3). Alternatively, the auto-reset function can be activated by a connection (A3/X2). ; If less than 4 safety edges are connected, the following diagram must be observed. |
| Note (applications) | Safety edges |
| Number of LEDs | 5 |
| Number of safety contacts | 1 |
| Number of signalling outputs | 1 |
| Number of undelayed semi-conductor outputs with signaling functi | 1 |
| Operating Current | 500 |
| Overvoltage category | III |
| Overvoltage category to VDE 0110 | 3 |
| PFH-value | 0.000000101 |
| Performance level, up to | d |
| Product group | HAWA: Electromechanical switchgear |
| Product name | SE-304C |
| Product type description | SE-304C |
| Protection class of Clips or Terminals | IP20 |
| Protection class of the Clearance | IP54 |
| Protection class of the enclosure | IP40 |
| Pull-in delay at RESET | 100 ms ... 2000 ms |
| Rated AC voltage for controls at DC minimum | 21.6 |
| Rated AC voltage for controls, 50 Hz, minimum | 21.6 |
| Rated control voltage at AC 50 Hz, maximum | 28.8 |
| Rated control voltage at DC, maximum | 28.8 |
| Rated impulse withstand voltage | 4 |
| Rated operating voltage | 24 VDC +20% / -10%; 24 VAC +10% / -10% |
| Reaction time, maximum | 17 |
| Reset after disconnection of supply voltage | Yes |
| Reset edge detection | Yes |
| Resistance to vibrations to EN 60068-2-6 | 10 … 55 Hz, amplitude 0.15 mm |
| Short-circuit recognition | Yes |
| Standards | ISO 13849-1; EN ISO 13850 |
| Start input | Yes |
| Terminal Connector | Screw connection |
| Utilisation category | DC-13; AC-15 |
| Utilisation category AC-15 | 230 |
| Utilisation category DC-13 | 24 |
| Width | 22.5 |
| Wire breakage detection | Yes |
| eCl@ss number, Version 9.0 | 27-37-18-19 |
| Weight | 175 |
|---|
| depth | 121 |
|---|
Documentația poate fi solicitată împreună cu produsul.