| AS-i Current consumption, maximum | 100 |
|---|
| AS-i Device protection | Internal short-circuit proof |
|---|
| AS-i Input, Channel 1 | Data bits DI 0 / DI 1 = dynamic code transmission |
|---|
| AS-i Input, Channel 2 | Data bits DI 2 / DI 3 = dynamic code transmission |
|---|
| AS-i Operating voltage AS-i maximum | 31.6 |
|---|
| AS-i Operating voltage, minimum | 26.5 |
|---|
| AS-i Outputs, DO 0 | Solenoid control |
|---|
| AS-i Outputs, DO 1 | No Function |
|---|
| AS-i Outputs, DO 2 | No Function |
|---|
| AS-i Outputs, DO 3 | No Function |
|---|
| AS-i Parameter bits, P0 | Actuator detected |
|---|
| AS-i Parameter bits, P1 | Solenoid interlock locked |
|---|
| AS-i Parameter bits, P2 | Magnet voltage in tolerance range |
|---|
| AS-i Parameter bits, P3 | Error message - locking/unlocking of the solenoid interlock blocked |
|---|
| AS-i Profile | S-7.B.F.E |
|---|
| AS-i Specification | Safety-Slave |
|---|
| AS-i Version | V 2.1 |
|---|
| AS-i, ID-Code | 0xB |
|---|
| AS-i, ID-Code1 | 0xF |
|---|
| AS-i, ID-Code2 | 0xE |
|---|
| AS-i, IO-Code | 0x7 |
|---|
| Active principle | electromechanical |
|---|
| Actuating play in direction of actuation | 5.5 |
|---|
| Actuating speed, maximum | 2 |
|---|
| Actuator monitored | Yes |
|---|
| Ambient temperature, maximum | 60 |
|---|
| Ambient temperature, minimum | -25 |
|---|
| Basic quantity unit | Piece |
|---|
| Certificates | cULus; TÜV; EAC; ASi-SaW |
|---|
| Clamping force | 2000 |
|---|
| Connector position | Bottom |
|---|
| Control category to EN13849 | 3 |
|---|
| Degree of pollution to VDE 0100 | 3 |
|---|
| EAN ( European Article Number) | 4030661396439 |
|---|
| EAN (European Article Number) | 4030661396439 |
|---|
| Enclosure material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
|---|
| Fuse rating | 4 |
|---|
| Gross weight | 450.000 |
|---|
| Height of sensor | 90 |
|---|
| Included in delivery | Actuators must be ordered separately. |
|---|
| Integral System Diagnostics, status | Yes |
|---|
| Latching force | 30 |
|---|
| Length of sensor | 30 |
|---|
| Manual release | Yes |
|---|
| Mechanical life, minimum | 1000000 |
|---|
| Mission Time | 20 |
|---|
| Net weight | 450.000 |
|---|
| Note (AS-i Parameter bits) | Set the parameter outputs to "1111" (0xF) ; FID: periphery error |
|---|
| Note (AS-i Input module address) | Preset to address 0, can be changed through AS-interface bus master or hand-held programming device |
|---|
| Note (AS-i Operating voltage) | Protection against polarity reversal |
|---|
| Note (General) | Interlocks with the power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened. |
|---|
| Note (LED switching conditions display) | (1) LED yellow: Channel 2 / AS-i SaW Bit 2.3; (2) LED green/red (AS-i duo LED): Supply voltage / communication error / slave address = 0 / periphery error detected; (3) LED yellow: Channel 1 / AS-i SaW Bit 0.1 |
|---|
| Note (Manual release) | For maintenance, installation, etc. ; For manual release using M5 triangular key, available as accessory |
|---|
| Note (PFH-value) | up to max. 100,000 switching cycles/year |
|---|
| Note (Relative humidity) | non-condensing; non-icing |
|---|
| Note (applications) | sliding safety guard; removable guard; hinged safety guard |
|---|
| Number of actuating directions | 3 |
|---|
| Operating Current | 500 |
|---|
| Overvoltage category | III |
|---|
| Overvoltage category to VDE 0100 | 3 |
|---|
| PFH-value | 0.000000101 |
|---|
| PIN 1 | AS-i + |
|---|
| PIN 2 | Aux - (P) |
|---|
| PIN 3 | AS-Interface - |
|---|
| PIN 4 | Aux + (P) |
|---|
| Performance level, up to | d |
|---|
| Please note: | Einsetzbar wenn ein Fehlerausschluss für eine gefahrbringende Beschädigung der 1-kanaligen Mechanik zulässig ist und ein ausreichender Manipulationsschutz gewährleistet ist. |
|---|
| Power to lock | Yes |
|---|
| Product group | Initial |
|---|
| Product name | AZM 161 AS |
|---|
| Product type description | AZM 161 B ST1-AS RAP |
|---|
| Protection class (Operating resource) | 2 |
|---|
| Protection rating | II |
|---|
| Rated impulse withstand voltage | 0.8 |
|---|
| Rated insulation voltage | 32 VDC |
|---|
| Rated operating voltage | 24 VDC -15% / +10% (stabilised PELV) |
|---|
| Reaction time, maximum | 100 |
|---|
| Relative humidity, maximum | 95 |
|---|
| Relative humidity, minimum | 30 |
|---|
| Resistance to vibrations to EN 60068-2-6 | 10 Hz ... 150 Hz, amplitude 0.35 mm |
|---|
| Restistance to shock | 30 g / 11 ms |
|---|
| Safety Integrity Level (SIL), applicable for | 2 |
|---|
| Standards | IEC 61508 |
|---|
| Storage and transport temperature, maximum | 85 |
|---|
| Storage and transport temperature, minimum | -25 |
|---|
| Terminal Connector | Connector plug M12, 4-pole, (A-coding) |
|---|
| Traceparts, external ID | 69-15022006-905757 |
|---|
| Traceparts, product ID | 33-22052019-077196 |
|---|
| Width of sensor | 130 |
|---|
| eCl@ss number, Version 9.0 | 27-27-26-03 |
|---|