Caracteristici
| AS-i Current consumption, maximum | 100 |
|---|---|
| AS-i Device protection | Internal short-circuit proof |
| AS-i Input, Channel 1 | Data bits DI 0 / DI 1 = dynamic code transmission |
| AS-i Input, Channel 2 | Data bits DI 2 / DI 3 = dynamic code transmission |
| AS-i Operating voltage AS-i maximum | 31.6 |
| AS-i Operating voltage, minimum | 26.5 |
| AS-i Outputs, DO 0 | Solenoid control |
| AS-i Outputs, DO 1 | No Function |
| AS-i Outputs, DO 2 | No Function |
| AS-i Outputs, DO 3 | No Function |
| AS-i Parameter bits, P0 | Safety guard and actuator detected |
| AS-i Parameter bits, P1 | Solenoid interlock locked |
| AS-i Parameter bits, P2 | No function |
| AS-i Parameter bits, P3 | No function |
| AS-i Profile | S-7.B.F.E |
| AS-i Specification | Safety-Slave |
| AS-i Version | V 2.1 |
| AS-i, ID-Code | 0xB |
| AS-i, ID-Code1 | 0xF |
| AS-i, ID-Code2 | 0xE |
| AS-i, IO-Code | 0x7 |
| Active principle | electromechanical |
| Actuating speed, maximum | 2 |
| Actuator monitored | Yes |
| Ambient temperature, maximum | 55 |
| Ambient temperature, minimum | -25 |
| Basic quantity unit | Piece |
| Certificates | cULus; TÜV; EAC; ASi-SaW |
| Clamping force | 1000 |
| Control category to EN13849 | 1 |
| Degree of pollution to VDE 0100 | 3 |
| EAN ( European Article Number) | 4030661390420 |
| EAN (European Article Number) | 4030661390420 |
| Enclosure material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| Gross weight | 300.000 |
| Height of sensor | 75.5 |
| Included in delivery | Actuators must be ordered separately. |
| Integral System Diagnostics, status | Yes |
| Latching force | 5 |
| Mechanical life, minimum | 1000000 |
| Mission Time | 20 |
| Net weight | 300.000 |
| Note (AS-i Parameter bits) | Set the parameter outputs to "1111" (0xF) ; FID: periphery error |
| Note (AS-i Input module address) | Preset to address 0, can be changed through AS-interface bus master or hand-held programming device |
| Note (AS-i Operating voltage) | Protection against polarity reversal |
| Note (General) | Interlocks with the power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened. |
| Note (LED switching conditions display) | (1) LED green: Supply voltage; (3) LED yellow : Enabling status ; (2) red LED: Communication error / Slave address = 0 |
| Note (PFH-value) | up to max. 100,000 switching cycles/year |
| Note (Relative humidity) | non-condensing; non-icing |
| Number of actuating directions | 2 |
| Overvoltage category to VDE 0100 | 3 |
| PFH-value | 0.00000116 |
| PIN 1 | AS-i + |
| PIN 2 | Aux - (P) |
| PIN 3 | AS-Interface - |
| PIN 4 | Aux + (P) |
| Performance Level | c |
| Power to unlock | Yes |
| Product group | Initial |
| Product name | AZM 170 AS |
| Product type description | AZM 170 B ST-AS P |
| Protection class (Operating resource) | 2 |
| Rated impulse withstand voltage | 0.8 |
| Rated insulation voltage | 32 VDC |
| Reaction time, maximum | 100 |
| Relative humidity, maximum | 95 |
| Relative humidity, minimum | 30 |
| Safety Integrity Level (SIL) | 1 |
| Standards | IEC 61508 |
| Storage and transport temperature, maximum | 85 |
| Storage and transport temperature, minimum | -25 |
| Terminal Connector | Connector plug M12, 4-pole, (A-coding) |
| Traceparts, external ID | 69-15022006-905849 |
| Width of sensor | 90 |
| eCl@ss number, Version 9.0 | 27-27-26-03 |
Housing
| Weight | 310 |
|---|
ambient conditions
| protection class | IP 67 to IEC/EN 60529 |
|---|