Sari la conținut

103014764

Preț la cerere

Cod produs 103014764

Disponibilitate La cerere

Solicită produs
SKU: OC-10632 Categorie: Brand:

Descriere

  • Safety sensor, electronic
  • Thermoplastic enclosure
  • Small body, high switching distance
  • Protection class IP65 / IP67
  • Repeated individual coding with RFID technology
  • Coding level „High” according to ISO 14119

Caracteristici

AS-i Current consumption, maximum100
AS-i Device protectionInternal short-circuit proof
AS-i Input, Channel 1Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input, Channel 2Data bits DI 2 / DI 3 = dynamic code transmission
AS-i Operating voltage AS-i maximum31.6
AS-i Operating voltage, minimum18
AS-i Outputs, DO 0 … DO 3No Function
AS-i Parameter bits, P0Actuator in
AS-i Parameter bits, P1Enabling inhibit (tamper protection time) active (FID))
AS-i Parameter bits, P2Enabling inhibit (tamper protection time) active (FID)
AS-i Parameter bits, P3Internal device error (FID)
AS-i Profile S-0.B.F.E
AS-i SpecificationSafety-Slave
AS-i Version V 2.1
AS-i, ID-Code0xB
AS-i, ID-Code10xF
AS-i, ID-Code20xE
AS-i, IO-Code0x0
Active principleRFID
Ambient temperature, maximum60
Ambient temperature, minimum-25
Basic quantity unitPiece
CertificatescULus; TÜV; EAC; FCC; ASi-SaW
CodingYes
Coding level according to ISO 14119High
Control category to EN138494
Degree of pollution to VDE 01003
Duration of risk, maximum200
EAN (European Article Number)4030661507620
Enclosure materialThermoplastic hotmelt
Ensured switch distance "OFF" S<sub>ar</sub>, lateral15
Ensured switching distance "OFF", front18
Ensured switching distance "ON", front10
Ensured switching distance "ON", side6
Gross weight83.000
Height of sensor29.5
Hysteresis (Switch distance), maximum2
Included in deliveryActuators must be ordered separately.
Integral System Diagnostics, status Yes
Length of cable0.25
Length of sensor18
Mission Time20
Net weight83.000
Note (AS-i Parameter bits)Set the parameter outputs to "1111" (0xF) ; FID: periphery error
Note (AS-i Input module address)Preset to address 0, can be changed through AS-interface bus master or hand-held programming device
Note (AS-i Operating voltage)Protection against polarity reversal
Note (LED switching conditions display)(1) green/red LED (AS-i Duo LED):Supply voltage / communication error / slave address = 0 / periphery error detected / Tamper protection time active; (2) yellow LED: device condition (enabling status) / hysteresis signal / device error
Number of actuating directions2
Overvoltage categoryIII
Overvoltage category to VDE 01003
PFD value0.0000689
PFH-value0.000000000393
PIN 1AS-Interface +
PIN 2n.c. (≤ 30 VDC)
PIN 3AS-Interface -
PIN 4n.c. (≤ 30 VDC)
Performance level, up toe
Product groupInitial
Product nameRSS260 AS
Protection class (Operating resource)3
Protection ratingIII
Rated impulse withstand voltage0.8
Rated insulation voltage32 VDC
Reaction time, maximum100
Recommendation (actuator)RST260-1
Repeat accuracy R0.5
Resistance to vibrations to EN 60068-2-610 … 55 Hz, amplitude 1 mm
Restistance to shock30 g / 11 ms
Safety Integrity Level (SIL), applicable for3
StandardsIEC 61508
Storage and transport temperature, maximum85
Storage and transport temperature, minimum-25
Switch distance12 mm; 9 mm (in case of approach from side)
Switching frequency, maximum1
Terminal ConnectorConnecting cable with M12 connector, straight, 4-pole
Time to readiness, maximum2000
Width of sensor40
eCl@ss number, Version 9.027-27-24-03
general informationIndividual coding, multiple teaching

Safety-relevant key characteristics

Safety functionsYes

Housing

Weight29

ambient conditions

protection classIP 67 to IEC/EN 60529; IP 65 to IEC/EN 60529

Documentația poate fi solicitată împreună cu produsul.

Desenele pot fi solicitate împreună cu produsul.

Parteneri

Contact rapid