Sari la conținut

AES 2555

Preț la cerere

Cod produs 101181684

Solicită produs
SKU: OC-8677 Categorie: Brand:

Caracteristici

Ambient temperature, maximum55
Automatic reset functionYes
Basic quantity unitPiece
Cable section, maximum2.5 mm²
Cable section, minimum0.25 mm²
CertificatescULus; EAC; DGUV
Climatic stressEN 60068-2-3; BG-GS-ET-14
Conduction resistance, maximum40
Contact resistance, maximum0.1
Degree of pollution to IEC/EN 60664-12
Drop-out delay in case of emergency, typically20
Drop-out delay in case of power failure, typically80
EAN ( European Article Number)4030661323121
EAN (European Article Number)4030661323121
Electrical power consumption5
Enclosure materialGlass-fibre, reinforced thermoplastic
FaultsFailure of door contacts to open or close; Cross-wire or short-circuit monitoring of the switch connections; Interruption of the switch connections; Failure of the safety relay to pull-in or drop-out; Fault on the input circuits or the relay control circuits of the safety monitoring module
Feedback circuit Yes
Frequency range50; 60
Gross weight319.000
Height100
Input resistance at GND4000
Input signal, HIGH Signal "1"10 … 30 VDC
Input signal, LOW Signal "0"0 … 2 VDC
Integral System Diagnostics, status Yes
Material of the contacts, electricalAg-Ni 10 and 0.2 µm gold-plated
Mechanical life, minimum20000000
MountingSnaps onto standard DIN rail to EN 60715
Net weight319.000
Note (Contact resistance)in new state
Note (Delivery capacity)Phased-out product
Note (General)Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Note (ISD -Faults)The following faults are registered by the safety monitoring modules and indicated by ISD.
Note (Wiring diagram)The wiring diagram is shown with guard doors closed and in de-energised condition.; Monitoring 2 guard door(s), each with a magnetic safety sensor of the BNS range; To secure a guard door up to PL d and Category 3; If one or two external relays or contactors are used to switch the load, the system can then only be classified in Category 3 to EN ISO 13849-1, if exclusion of the fault “Failure of the external contactors” can be substantiated and is documented, e.g. by using reliable down-rated contactors. A second contactor leads to an increase in the level of security by redundant switching to switch the load off.; The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix.
Note (applications)Safety sensor; Guard system
Number of LEDs1
Number of auxiliary contacts1
Number of openers2
Number of safety contacts4
Number of shutters2
Number of signalling outputs2
Number of undelayed semi-conductor outputs with signaling functi2
Product groupInitial
Product nameAES 255x
Product type descriptionAES 2555
Protection class of Clips or TerminalsIP20
Protection class of the ClearanceIP54
Protection class of the enclosureIP40
Pull-in delay at RESET, typically20
Pull-in delay at automatic start, maximum, typically100
Rated AC voltage for controls at DC minimum20.4
Rated AC voltage for controls, 50 Hz, minimum20.4
Rated AC voltage for controls, 60 Hz, minimum20.4
Rated control voltage at AC 50 Hz, maximum253
Rated control voltage at AC 60 Hz, maximum253
Rated control voltage at DC, maximum253
Rated impulse withstand voltage4
Rated operating voltage24 ... 230 VAC/DC
Reset after disconnection of supply voltage Yes
Resistance to vibrations to EN 60068-2-610...55 Hz, Amplitude 0.35 mm, ± 15 %
Restistance to shock30 g / 11 ms
Short-circuit recognitionYes
StandardsIEC 61508; ISO 13849-1
Storage and transport temperature, maximum70
Storage and transport temperature, minimum-25
Switching capacity, maximum250
Switching capacity, minimum10
Terminal ConnectorScrew connection; rigid or flexible
Terminal designationsIEC/EN 60947-1
Thermal test current6
Tightening torque of Clips0.6
Width45
Wire breakage detection Yes
eCl@ss number, Version 9.027-37-18-19

Housing

Weight300

mechanical data

depth121