Sari la conținut

AES1185.3-24VAC

Preț la cerere

Cod produs 101131929

Disponibilitate La cerere

Solicită produs
SKU: OC-7569 Categorie: Brand:

Descriere

  • Monitoring of BNS range magnetic safety sensors
  • 1 safety contact, STOP 0

Caracteristici

Ambient temperature, maximum55
Automatic reset functionYes
Basic quantity unitPiece
Cable section, maximum2.5 mm²
CertificatescULus; EAC
Climatic stressBG-GS-ET-14; IEC 60947-5-3
Conduction resistance, maximum40
Contact resistance, maximum0.1
Control category to EN138493
Current, Utilisation category AC-156
Current, Utilisation category DC120.1
Current, Utilisation category DC136
Degree of pollution to IEC/EN 60664-12
Drop-out delay in case of emergency, typically20
Drop-out delay in case of power failure, typically80
EAN ( European Article Number)4030661279442
EAN (European Article Number)4030661279442
EMC ratingEMC-Directive
Earth connection detectionYes
Electrical power consumption5
Enclosure materialGlass-fibre, reinforced thermoplastic
FaultsFailure of door contacts to open or close; Cross-wire or short-circuit monitoring of the switch connections; Interruption of the switch connections; Failure of the safety relay to pull-in or drop-out; Fault on the input circuits or the relay control circuits of the safety monitoring module
Feedback circuit Yes
Frequency range50; 60
Gross weight150.000
Height75
Input resistance at GND5000
Input signal, HIGH Signal "1"12 … 30 VDC
Input signal, LOW Signal "0"0 … 2 VDC
Integral System Diagnostics, status Yes
Material of the contacts, electricalAg-Ni, Au
Mechanical life, minimum50000000
Mission Time20
MountingSnaps onto standard DIN rail to EN 60715
Net weight150.000
Note (Contact resistance)in new state
Note (Delivery capacity)Phased-out product
Note (General)Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Note (ISD -Faults)The following faults are registered by the safety monitoring modules and indicated by ISD.
Note (Wiring diagram)The wiring diagram is shown with guard doors closed and in de-energised condition.; The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix.; Expansion of enable delay time: The enable delay time can be increased from 0.1 s to 1 s by changing the position of a jumper link connection under the cover of the unit.; To secure 3 guard doors up to PL d and Category 3; Monitoring 3 guard door(s), each with a magnetic safety sensor of the BNS range; The feedback circuit monitors the position of the contactors K3 and K4.; Start push button: A start push button (NO) can optionally be connected into the feedback circuit. With the guard door closed, the enabling paths are then not closed until the start push button has been operated.; If neither start button nor feedback circuit are connected, a jumper connection must be mounted between X1 and S13.; If only one external relay or contactor is used to switch the load, the system can be classified in Control Category 3 to ISO 13849-1, if exclusion of the fault “Failure of the external contactor” can be substantiated and is documented, e.g. by using a reliable down-rated contactor. A second contactor leads to an increase in the level of security by redundant switching to switch the load off.
Note (applications)Safety sensor; Guard system
Noticefor max. 50,000 switching cycles/year and max. 80% contact load
Number of LEDs1
Number of inputs for NC3
Number of inputs for NO3
Number of openers3
Number of safety contacts1
Number of shutters3
Overvoltage categoryIII
PFH-value0.0000001
Performance level, up tod
Product groupInitial
Product nameAES 118x
Product type descriptionAES 1185.3
Protection class of Clips or TerminalsIP20
Protection class of the ClearanceIP54
Protection class of the enclosureIP40
Pull-in delay at RESET, typically20
Pull-in delay at automatic start, maximum, typically100
Rated AC voltage for controls at DC minimum20.4
Rated AC voltage for controls, 50 Hz, minimum20.4
Rated AC voltage for controls, 60 Hz, minimum20.4
Rated control voltage at AC 50 Hz, maximum26.4
Rated control voltage at AC 60 Hz, maximum26.4
Rated control voltage at DC, maximum28.8
Rated impulse withstand voltage4
Rated operating voltage24 VAC -15% / +10%; 24 VDC -10%/+20%, residual ripple max. 10%
Reset after disconnection of supply voltage Yes
Resistance to vibrations to EN 60068-2-610...55 Hz, Amplitude 0.35 mm, ± 15 %
Restistance to shock30 g / 11 ms
Safety Integrity Level (SIL), applicable for2
Short-circuit recognitionYes
StandardsIEC 61508; ISO 13849-1
Storage and transport temperature, maximum70
Storage and transport temperature, minimum-25
Switching capacity, maximum250
Switching capacity, minimum10
Terminal ConnectorScrew connection; rigid or flexible
Terminal designationsIEC/EN 60947-1
Thermal test current4
Tightening torque of Clips0.6
Voltage, Utilisation category AC15230
Voltage, Utilisation category DC1224
Voltage, Utilisation category DC1324
Width22.5
Wire breakage detection Yes
eCl@ss number, Version 9.027-37-18-19

Housing

Weight150

mechanical data

depth110

Documentația poate fi solicitată împreună cu produsul.