Caracteristici
| Ambient temperature, maximum | 55 |
|---|---|
| Automatic reset function | Yes |
| Basic quantity unit | Piece |
| Cable section, maximum | 4 mm² |
| Certificates | cULus; EAC; DGUV |
| Conduction resistance, maximum | 40 |
| Contact resistance, maximum | 0.1 |
| Degree of pollution to IEC/EN 60664-1 | 2 |
| Drop-out delay in case of emergency, typically | 20 |
| Drop-out delay in case of power failure, typically | 80 |
| EAN ( European Article Number) | 4030661281360 |
| EAN (European Article Number) | 4030661281360 |
| Electrical power consumption | 8 |
| Enclosure material | Glass-fibre, reinforced thermoplastic |
| Faults | Failure of door contacts to open or close; Cross-wire or short-circuit monitoring of the switch connections; Interruption of the switch connections; Fault on the input circuits or the relay control circuits of the safety monitoring module |
| Feedback circuit | Yes |
| Frequency range | 50; 60 |
| Gross weight | 379.000 |
| Height | 100 |
| Input resistance at GND | 2000 |
| Input signal, HIGH Signal "1" | 10 … 30 VDC |
| Input signal, LOW Signal "0" | 0 … 2 VDC |
| Integral System Diagnostics, status | Yes |
| Mounting | Snaps onto standard DIN rail to EN 60715 |
| Net weight | 379.000 |
| Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
| Note (Contact resistance) | in new state |
| Note (Delivery capacity) | Phased-out product |
| Note (General) | Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. |
| Note (ISD -Faults) | The following faults are registered by the safety monitoring modules and indicated by ISD. |
| Note (Wiring diagram) | The wiring diagram is shown with guard doors closed and in de-energised condition.; The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix.; Start push button: A start push button (NO) can optionally be connected into the feedback circuit. With the guard door closed, the enabling paths are then not closed until the start push button has been operated.; The feedback circuit monitors the position of the positive-guided NC contacts of the contactors K3 and K4.; To secure 4 guard doors up to PL d and Category 3; Monitoring 4 guard door(s), each with a magnetic safety sensor of the BNS range; The NC contacts of the external contactors must be wired in series to X1 (+) and X2.; If less than 4 switches are connected, the unused terminals S21/S22 must be bridged before a NC contact is connected. This applies to the position of the jumpers in the safety-monitoring module with NC/NO configuration.; The switch (H6) connected to terminals X3 and X4 switches the enabling outputs Y14 and Y24 on and off with the guard door closed. If no switch is connected, a jumper connection must be mounted between the terminals X3 and X4. |
| Note (applications) | Safety sensor; Guard system |
| Number of LEDs | 1 |
| Number of openers | 4 |
| Number of safety contacts | 2 |
| Number of shutters | 4 |
| Number of signalling outputs | 4 |
| Number of undelayed semi-conductor outputs with signaling functi | 4 |
| Product group | Initial |
| Product name | AES 3075 |
| Product type description | AES 3075 |
| Protection class of Clips or Terminals | IP20 |
| Protection class of the Clearance | IP54 |
| Protection class of the enclosure | IP40 |
| Pull-in delay at RESET, typically | 20 |
| Pull-in delay at automatic start, maximum, typically | 100 |
| Rated AC voltage for controls at DC minimum | 20.4 |
| Rated AC voltage for controls, 50 Hz, minimum | 20.4 |
| Rated AC voltage for controls, 60 Hz, minimum | 20.4 |
| Rated control voltage at AC 50 Hz, maximum | 26.4 |
| Rated control voltage at AC 60 Hz, maximum | 26.4 |
| Rated control voltage at DC, maximum | 28.8 |
| Rated impulse withstand voltage | 0.5 |
| Rated operating voltage | 24 VAC -15% / +10%; 24 VDC -10%/+20%, residual ripple max. 10% |
| Resistance to vibrations to EN 60068-2-6 | 10...55 Hz, Amplitude 0.35 mm, ± 15 % |
| Restistance to shock | 30 g / 11 ms |
| Short-circuit recognition | Yes |
| Standards | IEC 61508; ISO 13849-1 |
| Start input | Yes |
| Storage and transport temperature, maximum | 70 |
| Storage and transport temperature, minimum | -25 |
| Switching capacity, maximum | 250 |
| Switching capacity, minimum | 10 |
| Terminal Connector | Screw connection |
| Thermal test current | 4 |
| Tightening torque of Clips | 0.4 |
| Width | 75 |
| Wire breakage detection | Yes |
| eCl@ss number, Version 9.0 | 27-37-18-19 |
Housing
| Weight | 300 |
|---|
mechanical data
| depth | 110 |
|---|