Sari la conținut

AZR 31S1 – 2SEC. -230VAC (STILLSTANDSWÄC

Preț la cerere

Cod produs 101179105

Disponibilitate La cerere

Solicită produs
SKU: OC-8607 Categorie: Brand:

Descriere

  • Fail-safe standstill monitors
  • Sensor-free detection of standstill by monitoring e.m.f.
  • Direct connection to three-phase motors
  • Suitable for connection to a frequency converter with the following interface date: rotary hysteresis 0 … 1000 Hz; switching frequency of the end level up to 16 kHz; engine voltage range 0 … 400 V
  • This fail-safe standstill monitor has the particular advantage that no adjustment for a required-value is needed during comissioning.
  • 3 safety contacts, STOP 0
  • 1 Signalling output

Caracteristici

Ambient temperature, maximum45
Ambient temperature, minimum-25
Automatic reset functionYes
Basic quantity unitPiece
Cable length (Master/Slave), maximum10
Cable section, maximum2.5 mm²
Cable section, minimum0.25 mm²
Category, Stop 04
CertificatesEAC
Climatic stressEN 60068-2-78
Common Cause Failure (CCF), minimum65
Conduction resistance, maximum40
Contact resistance, maximum0.1
Current, Utilisation category AC-156
Current, Utilisation category DC120.1
Current, Utilisation category DC136
Degree of pollution to IEC/EN 60664-12
Diagnostic Coverage (DC) Level, Stop 0≥ 99
Drop-out delay in case of "emergency stop", maximum15
Drop-out delay in case of emergency, typically20
Drop-out delay in case of power failure, typically80
EAN (European Article Number)4030661446554
EMC ratingEMC-Directive
Earth connection detectionYes
Electrical power consumption, maximum4
Enclosure materialGlass-fibre, reinforced thermoplastic
Feedback circuit Yes
Frequency range50; 60
Gross weight400.000
Height73.2
Indicated operating statesOUT, green: release; ON, green: supply voltage U<sub>B</sub>; ERR, red: error channel A + B
Integral System Diagnostics, status Yes
Material of the contacts, electricalAgSn0. self-cleaning, positive drive
Mechanical life, minimum10000000
Mission Time20
MountingSnaps onto standard DIN rail to EN 60715
Net weight400.000
Note (Contact resistance)in new state
Note (General)Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Note (Wiring diagram)The wiring diagram is shown with guard doors closed and in de-energised condition.; The sensor-free standstill monitor checks the e.m.f. of the three phase motor.; The SRB range guard door monitor checks the position of the guard door. ; Monitoring the guard door using a solenoid interlock and a safety switch with separate actuator (A and B).; Release takes place by means of the NO contact (E) only when the run-down movement has been terminated.; After release has taken place, the guard door must be opened.; To secure a guard door
Note (applications)safe standstill monitoring
Number of LEDs5
Number of auxiliary contacts1
Number of safety contacts3
Overvoltage categoryIII
PFH-value0.00000002
Performance level, stop 0, up toe
Product groupInitial
Product nameAZR 31S1
Product type descriptionAZR31S1-2SEC/230VAC
Protection class of Clips or TerminalsIP20
Protection class of the ClearanceIP54
Protection class of the enclosureIP40
Pull-in delay at RESET, typically20
Pull-in delay at automatic start (after detecting standstill), a2000
Rated AC voltage for controls, 50 Hz, minimum195.5
Rated AC voltage for controls, 60 Hz, minimum195.5
Rated control voltage at AC 50 Hz, maximum253
Rated control voltage at AC 60 Hz, maximum253
Rated impulse withstand voltage4
Rated operating voltage230 VAC -15% / +10%
Resistance to vibrations to EN 60068-2-610 ... 55 Hz, Amplitude 0.35 mm
Restistance to shock30 g / 11 ms
Safety Integrity Level (SIL), Stop 0, applicable for3
Short-circuit recognitionYes
StandardsIEC 61508; EN 60947-5-1
Storage and transport temperature, maximum85
Storage and transport temperature, minimum-40
Switching capacity, maximum250
Switching capacity, minimum10
Terminal ConnectorScrew connection; rigid or flexible
Terminal designationsIEC/EN 60947-1
Tightening torque of Clips0.6
Voltage, Utilisation category AC15230
Voltage, Utilisation category DC1224
Voltage, Utilisation category DC1324
Width45
Wire breakage detection Yes
eCl@ss number, Version 9.027-37-18-19

Housing

Weight400

mechanical data

depth121

Documentația poate fi solicitată împreună cu produsul.

Desenele pot fi solicitate împreună cu produsul.

Parteneri

Contact rapid

Discută cu SensoData

Telefon WhatsApp E-mail Facebook