Sari la conținut

SRB324-ST-24V (V3)

Preț la cerere

Cod produs 101195504

Disponibilitate La cerere

Solicită produs
SKU: OC-9217 Categorie: Brand:

Descriere

  • Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
  • Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
  • 3 safety contacts, STOP 0;
    2 safety contacts, STOP 1 (adjustable 1 … 30 s)
  • 4 Signalling outputs
  • Optional: Short-circuit recognition, Manual reset with edge detection in fail-safe circuit, Automatic reset function

Caracteristici

Ambient temperature, maximum60
Ambient temperature, minimum-25
Automatic reset functionYes
Basic quantity unitPiece
Cable section, maximum2.5 mm²
Cable section, minimum0.25 mm²
Category, Stop 04
Category, Stop 13
CertificatescULus; TÜV; EAC; TILVA
Climatic stressEN 60068-2-78
Common Cause Failure (CCF), minimum65
Conduction resistance, maximum40
Contact resistance, maximum0.1
Current, Utilisation category DC120.1
Current, Utilisation category, AC153
Current, Utilisation category, DC132
Degree of pollution to VDE 01102
Diagnostic Coverage (DC) Level, Stop 0≥ 99
Diagnostic Coverage (DC) Level, Stop 1> 60
Drop-out delay in case of emergency, typically30
Drop-out delay in case of power failure, typically80
EAN ( European Article Number)4030661446547
EAN (European Article Number)4030661446547
EMC ratingEMC-Directive
EPLANYes
Earth connection detectionYes
Electrical power consumption3.2
Electronic FuseYes
Enclosure materialGlass-fibre reinforced thermoplastic, ventilated
Feedback circuit Yes
Frequency range50; 60
Gross weight480.000
Height100
Indicated operating statesPosition relay K2; Position relay K1; Internal operating voltage U<sub>i</sub>; Position relay K3
Integral System Diagnostics, status Yes
Material of the contacts, electricalAgSn0, Ag-Ni, self-cleaning, positive drive
Mechanical life, minimum10000000
Mission Time20
MountingSnaps onto standard DIN rail to EN 60715
Net weight480.000
Note (Contact resistance)in new state
Note (General)Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Note (Wiring diagram)The wiring diagram is shown with guard doors closed and in de-energised condition.; The control recognises cross-short, cable break and earth leakages in the monitoring circuit.; 2 channel control shown for a guard-door monitor with two contacts, of which at least one contact has positive break, with external reset button (R).; (H2) = Feedback circuit
Note (applications)Safety sensor; Guard system; Emergency-Stop button; Pull-wire emergency stop switches; Safety light curtain
Number of LEDs6
Number of Safety contacts, STOP 03
Number of Safety contacts, STOP 12
Number of auxiliary contacts1
Number of openers2
Number of safety contacts5
Number of signalling outputs3
Overvoltage categoryIII
PFD value0.000053
PFH-Value Stop 00.00000002
PFH-Value Stop 10.0000002
Performance level, stop 0, up toe
Performance level, stop 1, up tod
Product groupInitial
Product nameSRB324ST
Product type descriptionSRB324ST 24V (V.3)
Protection class of Clips or TerminalsIP20
Protection class of the ClearanceIP54
Protection class of the enclosureIP40
Pull-in delay at RESET, typically20
Pull-in delay at automatic start, maximum, typically250
Rated AC voltage for controls at DC minimum20.4
Rated AC voltage for controls, 50 Hz, minimum20.4
Rated AC voltage for controls, 60 Hz, minimum20.4
Rated control voltage at AC 50 Hz, maximum26.4
Rated control voltage at AC 60 Hz, maximum26.4
Rated control voltage at DC, maximum28.8
Rated impulse withstand voltage4
Rated operating voltage24 VAC -15% / +10%; 24 VDC -15% / +20%, residual ripple max. 10 %
Removable TerminalsYes
Replacement article number101179876
Reset edge detectionYes
Resistance to vibrations to EN 60068-2-610 ... 55 Hz, Amplitude 0.35 mm
Restistance to shock30 g / 11 ms
Safety Integrity Level (SIL), Stop 0, applicable for3
Safety Integrity Level (SIL), Stop 1, applicable for2
Short-circuit recognitionYes
StandardsIEC 61508; EN 60947-5-1
Start inputYes
Stop-Category0; 1
Storage and transport temperature, maximum85
Storage and transport temperature, minimum-40
Switching capacity, maximum24
Switching capacity, minimum10
Terminal ConnectorScrew connection; rigid or flexible
Terminal designationsIEC/EN 60947-1
Tightening torque of Clips0.6
Voltage, Utilisation category DC1224
Voltage, Utilisation category, AC15230
Voltage, Utilisation category, DC1324
Width45
Wire breakage detection Yes
eCl@ss number, Version 9.027-37-18-19

Housing

Weight435

mechanical data

depth121

Documentația poate fi solicitată împreună cu produsul.

Desenele pot fi solicitate împreună cu produsul.

Parteneri

Contact rapid

Discută cu SensoData