Descriere
- Fail-safe standstill monitors
- This fail-safe standstill monitor has the particular advantage that no adjustment for a required-value is needed during comissioning.
- 3 safety contacts, STOP 0
- Control category 4 to ISO 13849-1

| Ambient temperature, maximum | 45 |
|---|---|
| Ambient temperature, minimum | -25 |
| Automatic reset function | Yes |
| Basic quantity unit | Piece |
| Cable section, maximum | 2.5 mm² |
| Cable section, minimum | 0.5 mm² |
| Category, Stop 0 | 4 |
| Certificates | CCC; cULus; EAC |
| Climatic stress | EN 60068-2-78 |
| Common Cause Failure (CCF), minimum | 65 |
| Conduction resistance, maximum | 40 |
| Contact resistance, maximum | 0.1 |
| Current, Utilisation category AC-15 | 6 |
| Current, Utilisation category DC13 | 6 |
| Degree of pollution to IEC/EN 60664-1 | 2 |
| Diagnostic Coverage (DC) Level, Stop 0 | ≥ 99 |
| Drop-out delay in case of "emergency stop", maximum | 15 |
| EAN ( European Article Number) | 4250116202591 |
| EAN (European Article Number) | 4250116202591 |
| EMC rating | EMC-Directive |
| Earth connection detection | Yes |
| Electrical power consumption, maximum | 4 |
| Enclosure material | Glass-fibre, reinforced thermoplastic |
| Feedback circuit | Yes |
| Gross weight | 500.000 |
| Height | 83 |
| Indicated operating states | OUT, green: release; switching condition; UB: Supply voltage on; ERR: Error functional defect |
| Integral System Diagnostics, status | Yes |
| Material of the contacts, electrical | AgSn0 + Au, self-cleaning, positive drive |
| Mechanical life, minimum | 10000000 |
| Mission Time | 20 |
| Mounting | Snaps onto standard DIN rail to EN 60715 |
| Net weight | 500.000 |
| Note (Contact resistance) | in new state |
| Note (General) | Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. |
| Note (Wiring diagram) | OUT: Enabling safety contacts 13-14, 23-24 closed |
| Note (applications) | safe standstill monitoring |
| Number of LEDs | 5 |
| Number of auxiliary contacts | 1 |
| Number of safety contacts | 3 |
| Overvoltage category to IEC/EN 60664-1 | 3 |
| PFH-Value Stop 0 | 0.00000002 |
| Performance level, stop 0, up to | e |
| Product group | Initial |
| Product name | SSW 301HV |
| Product type description | SSW301HV-230V |
| Protection class of Clips or Terminals | IP20 |
| Protection class of the Clearance | IP54 |
| Protection class of the enclosure | IP40 |
| Pull-in delay at automatic start (after detecting standstill), a | 7000 |
| Rated AC voltage for controls, 50 Hz, minimum | 195.5 |
| Rated AC voltage for controls, 60 Hz, minimum | 195.5 |
| Rated control voltage at AC 50 Hz, maximum | 253 |
| Rated control voltage at AC 60 Hz, maximum | 253 |
| Rated impulse withstand voltage | 4 |
| Rated operating voltage | 230 VAC -15% / + 10% |
| Resistance to vibrations to EN 60068-2-6 | 10 ... 55 Hz, Amplitude 0.35 mm |
| Restistance to shock | 30 g / 11 ms |
| Safety Integrity Level (SIL), Stop 0, applicable for | 3 |
| Short-circuit recognition | Yes |
| Standards | IEC 61508; ISO 13849-1 |
| Storage and transport temperature, maximum | 85 |
| Storage and transport temperature, minimum | -40 |
| Switching capacity, maximum | 250 |
| Switching capacity, minimum | 10 |
| Terminal Connector | Screw connection; rigid or flexible |
| Terminal designations | IEC/EN 60947-1 |
| Tightening torque of Clips | 0.6 |
| Voltage, Utilisation category AC15 | 230 |
| Voltage, Utilisation category DC13 | 24 |
| Width | 90 |
| Wire breakage detection | Yes |
| eCl@ss number, Version 9.0 | 27-37-18-19 |
| Weight | 500 |
|---|
| depth | 127 |
|---|
Documentația poate fi solicitată împreună cu produsul.
Desenele pot fi solicitate împreună cu produsul.