Sari la conținut

ZQ-700-ST-AS

Preț la cerere

Cod produs 101215046

Disponibilitate La cerere

Solicită produs
SKU: OC-9835 Categorie: Brand:

Descriere

  • Thermoplastic enclosure
  • One tension force for cable lengths up to 10 m
  • Release push button
  • Position indicator
  • Twisting of towing eye not possible
  • wire pull and breakage detection
  • Double-insulated
  • Integrated AS-Interface
  • Suitable for AS-i Power24
  • AS-Interface M12 connector, bottom

Caracteristici

AS-i Device protectionInternal short-circuit proof
AS-i Input, Channel 1Data bits DI 0 / DI 1 = dynamic code transmission
AS-i Input, Channel 2Data bits DI 2 / DI 3 = dynamic code transmission
AS-i Operating voltage AS-i maximum31.6
AS-i Operating voltage, minimum18
AS-i Outputs, DO 0 … DO 3No Function
AS-i Parameter bits, P0Channel 2 switched
AS-i Parameter bits, P1No function
AS-i Parameter bits, P2No function
AS-i Parameter bits, P3No function
AS-i Profile S-0.B.F.F
AS-i Version V 3.0
AS-i, ID-Code0xB
AS-i, ID-Code10xF
AS-i, ID-Code20xF
AS-i, IO-Code0x0
Actuating force, maximum200
Actuating travel400
Ambient temperature, maximum60
Ambient temperature, minimum-25
Available until2020-12-31T00:00:00
Basic quantity unitPiece
CertificatescULus; EAC; ASi-SaW
Control category to EN138494
Degree of pollution to VDE 01003
EAN ( European Article Number)4030661404455
EAN (European Article Number)4030661404455
Enclosure materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
Gross weight230.000
Height of sensor182.5
Length of sensor51
Length of the wire, maximum10
Material of the coverPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
Mechanical life, minimum100000
Mission Time20
Net weight230.000
Note (AS-i Parameter bits)Set the parameter outputs to "1111" (0xF) ; FID: periphery error
Note (AS-i Input module address)Preset to address 0, can be changed through AS-interface bus master or hand-held programming device
Note (AS-i Operating voltage)Protection against polarity reversal
Note (Delivery capacity)Phased-out product
Note (General)Recommended cable lengths for pull-wire Emergency-Stop switches in relation to the range of ambient temperature.; As the thimbles are subject to deformation in case of wire pull, the wire should be pulled several times after fitting. After that, the wire must be re-tensioned using the eyebolt or the tensioner.; The addressing must take place via the M12 connector or the flat cable connection.; At 2 mm to 5 mm distance, intermediate wire supports are required, see accessories
Note (PFH-value)up to max. 5,000 switching cycles/year
Note (Relative humidity)non-condensing; non-icing
Operating Current50
Overvoltage categoryIII
Overvoltage category to VDE 01003
PFH-value0.000000014
PIN 1AS-Interface +
PIN 2n.c.
PIN 3AS-Interface -
PIN 4n.c.
Performance level, up toe
Product groupInitial
Product nameZQ 700 AS
Product type descriptionZQ 700 ST-AS
Protection class (Operating resource)2
Protection ratingII
Rated impulse withstand voltage0.8
Rated insulation voltage32 V
Reaction time, maximum100
Relative humidity, maximum95
Relative humidity, minimum30
Resistance to vibrations to EN 60068-2-610 … 150 Hz, amplitude 0.35 mm / 5 g
Restistance to shock15 g / 11 ms
Safety Integrity Level (SIL), applicable for3
StandardsIEC 61508
Storage and transport temperature, maximum85
Storage and transport temperature, minimum-25
Switching principleSnap switch element
Terminal ConnectorConnector plug M12, 4-pole, (A-coding)
Width of sensor40.5
eCl@ss number, Version 9.027-37-12-01

electrical data

switching frequency3600

ambient conditions

protection classIP67 to IEC 60529

Documentația poate fi solicitată împreună cu produsul.

Desenele pot fi solicitate împreună cu produsul.

Parteneri

Contact rapid

Discută cu SensoData