  • Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
  • Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
  • Fit for signal evaluation of outputs of safety magnetic switches
  • 3 safety contacts, STOP 0
  • 1 Signalling output

Caracteristici

Ambient temperature, maximum60
Ambient temperature, minimum-25
Automatic reset functionYes
Basic quantity unitPiece
Cable section, maximum2.5 mm²
Cable section, minimum0.25 mm²
Category, Stop 04
CertificatesCCC; cULus; TÜV; EAC; TILVA
Climatic stressEN 60068-2-78
Common Cause Failure (CCF), minimum65
Conduction resistance, maximum40
Contact resistance, maximum0.1
Current, Utilisation category AC-156
Current, Utilisation category DC136
Degree of pollution to IEC/EN 60664-12
Diagnostic Coverage (DC) Level, Stop 0≥ 99
Drop-out delay in case of emergency, typically20
Drop-out delay in case of power failure, typically80
EAN ( European Article Number)4030661476179
EAN (European Article Number)4030661521589
EMC ratingEMC-Directive
Earth connection detectionYes
Electrical power consumption2
Electronic FuseYes
Enclosure materialGlass-fibre reinforced thermoplastic, ventilated
Feedback circuit Yes
Frequency range50; 60
Gross weight250.000
Height120
Indicated operating statesPosition relay K2; Position relay K1; Internal operating voltage U<sub>i</sub>
Integral System Diagnostics, status Yes
Material of the contacts, electricalAgSn0. self-cleaning, positive drive
Mechanical life, minimum10000000
Mission Time20
MountingSnaps onto standard DIN rail to EN 60715
Net weight250.000
Note (Contact resistance)in new state
Note (General)Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Note (LED switching conditions display)QS: cross-wire short detection status (LED on when cross-wire short detection active).
Note (Wiring diagram)The wiring diagram is shown with guard doors closed and in de-energised condition.; Input level: The example shows a 2-channel control of a guard door monitoring with two position switches, whereof one with positive break, external reset button (R) and feedback circuit (H2).; Relay outputs: Suitable for 2 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts.; The control recognises cross-short, cable break and earth leakages in the monitoring circuit.; Switch setting: The cross-wire short detection function (factory default) is programmed by means of the switch located underneath the front cover of the module: Pposition nQS (top): no cross-wire short protection, suitable for 1-channel applications and applications with outputs with potential in the control circuits. Position QS (bottom): cross-wire short protection, suitable for 2-channel applications without outputs with potential in the control circuits.; For 1-channel control, connect NC contact to S11/S12 and bridge S12/S22 (QS-switch = nQS); Connect potential p-type outputs of safety light grids/curtains to S12/S22. The devices must have the same reference potential. QS-switch = nQS; Automatic start: The automatic start is programmed by connecting the feedback circuit to the terminals S12/X3. If the feedback circuit is not required, establish a bridge.; F1 = Hybrid fuse
Note (applications)Safety sensor; Guard system; Emergency-Stop button; Pull-wire emergency stop switches; Safety light barriers
Number of LEDs5
Number of auxiliary contacts1
Number of openers2
Number of safety contacts3
Overvoltage categoryIII
PFH-Value Stop 00.00000002
Performance level, stop 0, up toe
Product groupInitial
Product nameSRB301ST
Product type descriptionSRB301ST-24V-(V.2)
Protection class of Clips or TerminalsIP20
Protection class of the ClearanceIP54
Protection class of the enclosureIP40
Pull-in delay at RESET, typically20
Pull-in delay at automatic start, maximum, typically100
Rated AC voltage for controls at DC minimum20.4
Rated AC voltage for controls, 50 Hz, minimum20.4
Rated AC voltage for controls, 60 Hz, minimum20.4
Rated control voltage at AC 50 Hz, maximum26.4
Rated control voltage at AC 60 Hz, maximum26.4
Rated control voltage at DC, maximum28.8
Rated impulse withstand voltage4
Rated operating voltage24 VAC -15% / +10%; 24 VDC -15%/+20%, residual ripple max. 10%
Removable TerminalsYes
Reset edge detectionYes
Resistance to vibrations to EN 60068-2-610 ... 55 Hz, Amplitude 0.35 mm
Restistance to shock30 g / 11 ms
Safety Integrity Level (SIL), Stop 0, applicable for3
Short-circuit recognitionYes
StandardsIEC 61508; ISO 13849-1; EN 62061
Start inputYes
Storage and transport temperature, maximum85
Storage and transport temperature, minimum-40
Switching capacity, maximum250
Switching capacity, minimum10
Terminal ConnectorScrew connection, plug-in; rigid or flexible
Terminal designationsIEC/EN 60947-1
Tightening torque of Clips0.6
Voltage, Utilisation category AC15230
Voltage, Utilisation category DC1324
Width22.5
Wire breakage detection Yes
eCl@ss number, Version 9.027-37-18-19

Housing

Weight240

mechanical data

depth121

Documentația poate fi solicitată împreună cu produsul.