Descriere
- Monitoring of BNS range magnetic safety sensors
- 1 safety contact, STOP 0
- 2 Signalling outputs
| Ambient temperature, maximum | 55 |
|---|---|
| Automatic reset function | Yes |
| Basic quantity unit | Piece |
| Cable section, maximum | 2.5 mm² |
| Cable section, minimum | 0.25 mm² |
| Certificates | cULus; EAC |
| Climatic stress | EN 60068-2-3; BG-GS-ET-14 |
| Conduction resistance, maximum | 40 |
| Contact resistance, maximum | 0.1 |
| Control category to EN13849 | 3 |
| Current, Utilisation category AC-15 | 6 |
| Current, Utilisation category DC12 | 0.1 |
| Current, Utilisation category DC13 | 6 |
| Degree of pollution to IEC/EN 60664-1 | 2 |
| Drop-out delay in case of emergency, typically | 20 |
| Drop-out delay in case of power failure, typically | 80 |
| EAN ( European Article Number) | 4030661296937 |
| EAN (European Article Number) | 4030661296937 |
| EMC rating | EMC-Directive |
| Earth connection detection | Yes |
| Electrical power consumption | 5 |
| Enclosure material | Glass-fibre reinforced thermoplastic, ventilated |
| Faults | Failure of door contacts to open or close; Cross-wire or short-circuit monitoring of the switch connections; Interruption of the switch connections; Failure of the safety relay to pull-in or drop-out; Fault on the input circuits or the relay control circuits of the safety monitoring module |
| Frequency range | 50; 60 |
| Gross weight | 155.000 |
| Height | 100 |
| Input resistance at GND | 4000 |
| Input signal, HIGH Signal "1" | 10 … 30 VDC |
| Input signal, LOW Signal "0" | 0 … 2 VDC |
| Integral System Diagnostics, status | Yes |
| Material of the contacts, electrical | Ag-Ni 10 and 0.2 µm gold-plated |
| Mechanical life, minimum | 20000000 |
| Mission Time | 20 |
| Mounting | Snaps onto standard DIN rail to EN 60715 |
| Net weight | 155.000 |
| Note (Contact resistance) | in new state |
| Note (Delivery capacity) | Phased-out product |
| Note (General) | Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. |
| Note (ISD -Faults) | The following faults are registered by the safety monitoring modules and indicated by ISD. |
| Note (Wiring diagram) | The wiring diagram is shown with guard doors closed and in de-energised condition.; To secure a guard door up to PL d and Category 3; Monitoring 1 guard door(s), each with a magnetic safety sensor of the BNS range; If one or two external relays or contactors are used to switch the load, the system can then only be classified in Category 3 to EN ISO 13849-1, if exclusion of the fault “Failure of the external contactors” can be substantiated and is documented, e.g. by using reliable down-rated contactors. A second contactor leads to an increase in the level of security by redundant switching to switch the load off.; Modification for 2 NC contacts: The safety monitoring module can be modified to monitor two NC contacts by bridging the terminals A1 and X1. In this configuration, the short-circuit detection becomes inoperative.; Expansion of enable delay time: The enable delay time can be increased from 0.1 s to 1.0 s by changing the position of a jumper link connection under the cover of the unit.; The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix. |
| Note (applications) | Safety sensor; Guard system |
| Number of LEDs | 1 |
| Number of openers | 2 |
| Number of safety contacts | 1 |
| Number of shutters | 1 |
| Number of signalling outputs | 2 |
| Number of undelayed semi-conductor outputs with signaling functi | 2 |
| Overvoltage category | III |
| PFH-value | 0.0000001 |
| Performance level, up to | d |
| Product group | Initial |
| Product name | AES 113x |
| Product type description | AES 1136 |
| Protection class of Clips or Terminals | IP20 |
| Protection class of the Clearance | IP54 |
| Protection class of the enclosure | IP40 |
| Pull-in delay at RESET, typically | 20 |
| Pull-in delay at automatic start, maximum, typically | 100 |
| Rated AC voltage for controls at DC minimum | 20.4 |
| Rated AC voltage for controls, 50 Hz, minimum | 20.4 |
| Rated AC voltage for controls, 60 Hz, minimum | 20.4 |
| Rated control voltage at AC 50 Hz, maximum | 26.4 |
| Rated control voltage at AC 60 Hz, maximum | 26.4 |
| Rated control voltage at DC, maximum | 28.8 |
| Rated impulse withstand voltage | 4 |
| Rated operating voltage | 24 VAC -15% / +10%; 24 VDC -10%/+20%, residual ripple max. 10% |
| Resistance to vibrations to EN 60068-2-6 | 10...55 Hz, Amplitude 0.35 mm, ± 15 % |
| Restistance to shock | 30 g / 11 ms |
| Safety Integrity Level (SIL), applicable for | 2 |
| Short-circuit recognition | Yes |
| Standards | IEC 61508; ISO 13849-1 |
| Start-up test | Yes |
| Storage and transport temperature, maximum | 70 |
| Storage and transport temperature, minimum | -25 |
| Switching capacity, maximum | 250 |
| Switching capacity, minimum | 10 |
| Terminal Connector | Screw connection; rigid or flexible |
| Terminal designations | IEC/EN 60947-1 |
| Thermal test current | 6 |
| Tightening torque of Clips | 0.6 |
| Voltage, Utilisation category AC15 | 230 |
| Voltage, Utilisation category DC12 | 24 |
| Voltage, Utilisation category DC13 | 24 |
| Width | 22.5 |
| Wire breakage detection | Yes |
| eCl@ss number, Version 9.0 | 27-37-18-19 |
| Weight | 155 |
|---|
| depth | 121 |
|---|