AES1235 (24VDC)

Preț la cerere

Cod produs 101170049

Disponibilitate La cerere

Solicită produs
SKU: OC-8310 Categorie: Brand:

Descriere

  • Monitoring of BNS range magnetic safety sensors
  • 2 safety contacts, STOP 0
  • 2 Signalling outputs

Caracteristici

Ambient temperature, maximum55
Automatic reset functionYes
Basic quantity unitPiece
Cable section, maximum2.5 mm²
Cable section, minimum0.25 mm²
CertificatescULus; EAC
Climatic stressEN 60068-2-3; BG-GS-ET-14
Conduction resistance, maximum40
Contact resistance, maximum0.1
Control category to EN138493
Current, Utilisation category AC-156
Current, Utilisation category DC120.1
Current, Utilisation category DC136
Degree of pollution to IEC/EN 60664-12
Drop-out delay in case of emergency, typically20
Drop-out delay in case of power failure, typically80
EAN ( European Article Number)4030661297118
EAN (European Article Number)4030661297118
EMC ratingEMC-Directive
Earth connection detectionYes
Electrical power consumption5
Enclosure materialGlass-fibre reinforced thermoplastic, ventilated
FaultsFailure of door contacts to open or close; Cross-wire or short-circuit monitoring of the switch connections; Interruption of the switch connections; Failure of the safety relay to pull-in or drop-out; Fault on the input circuits or the relay control circuits of the safety monitoring module
Feedback circuit Yes
Frequency range50; 60
Gross weight240.000
Height100
Input resistance at GND4000
Input signal, HIGH Signal "1"10 … 30 VDC
Input signal, LOW Signal "0"0 … 2 VDC
Integral System Diagnostics, status Yes
Material of the contacts, electricalAg-Ni 10 and 0.2 µm gold-plated
Mechanical life, minimum20000000
Mission Time20
MountingSnaps onto standard DIN rail to EN 60715
Net weight240.000
Note (Contact resistance)in new state
Note (Delivery capacity)Phased-out product
Note (General)Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Note (ISD -Faults)The following faults are registered by the safety monitoring modules and indicated by ISD.
Note (Wiring diagram)The wiring diagram is shown with guard doors closed and in de-energised condition.; To secure a guard door up to PL d and Category 3; Monitoring 1 guard door(s), each with a magnetic safety sensor of the BNS range; The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix.; Expansion of enable delay time: The enable delay time can be increased from 0.1 s to 1 s by changing the position of a jumper link connection under the cover of the unit.; The feedback circuit monitors the position of the contactors K3 and K4.; Start push button: A start push button (NO) can optionally be connected into the feedback circuit. With the guard door closed, the enabling paths are then not closed until the start push button has been operated.; If only one external relay or contactor is used to switch the load, the system can be classified in Control Category 3 to ISO 13849-1, if exclusion of the fault “Failure of the external contactor” can be substantiated and is documented, e.g. by using a reliable down-rated contactor. A second contactor leads to an increase in the level of security by redundant switching to switch the load off.; If neither start button nor feedback circuit are connected, a jumper connection must be mounted between X1 and A1.; Modification for 2 NC contacts: The safety monitoring module can be modified to monitor two NC contacts by bridging the terminals A1 and X2. In this configuration, the short-circuit detection becomes inoperative.
Note (applications)Safety sensor; Guard system
Noticefor max. 50,000 switching cycles/year and max. 80% contact load
Number of LEDs1
Number of openers2
Number of safety contacts2
Number of shutters1
Number of signalling outputs2
Number of undelayed semi-conductor outputs with signaling functi2
Overvoltage categoryIII
PFH-value0.0000001
Performance level, up tod
Product groupInitial
Product nameAES 123x
Product type descriptionAES 1235
Protection class of Clips or TerminalsIP20
Protection class of the ClearanceIP54
Protection class of the enclosureIP40
Pull-in delay at RESET, typically20
Pull-in delay at automatic start, maximum, typically100
Rated AC voltage for controls at DC minimum20.4
Rated AC voltage for controls, 50 Hz, minimum20.4
Rated AC voltage for controls, 60 Hz, minimum20.4
Rated control voltage at AC 50 Hz, maximum26.4
Rated control voltage at AC 60 Hz, maximum26.4
Rated control voltage at DC, maximum28.8
Rated impulse withstand voltage4
Rated operating voltage24 VAC -15% / +10%; 24 VDC -10%/+20%, residual ripple max. 10%
Reset after disconnection of supply voltage Yes
Resistance to vibrations to EN 60068-2-610...55 Hz, Amplitude 0.35 mm, ± 15 %
Restistance to shock30 g / 11 ms
Safety Integrity Level (SIL), applicable for2
Short-circuit recognitionYes
StandardsIEC 61508; ISO 13849-1
Storage and transport temperature, maximum70
Storage and transport temperature, minimum-25
Switching capacity, maximum250
Switching capacity, minimum10
Terminal ConnectorScrew connection; rigid or flexible
Terminal designationsIEC/EN 60947-1
Thermal test current6
Tightening torque of Clips0.6
Voltage, Utilisation category AC15230
Voltage, Utilisation category DC1224
Voltage, Utilisation category DC1324
Width22.5
Wire breakage detection Yes
eCl@ss number, Version 9.027-37-18-19

Housing

Weight160

mechanical data

depth121