Descriere

  • Detects standstill using 2 impulse sensor(s)
  • 4 safety contacts
  • 1 Signalling output
  • 2 additional transistor outputs
  • 2 additional transistor outputs

Caracteristici

Ambient temperature, maximum55
Automatic reset functionYes
Basic quantity unitPiece
Cable section, maximum2.5 mm²
Cable section, minimum0.2 mm²
CertificatescULus; EAC
Climatic stressEN 60068-2-3; BG-GS-ET-14
Conduction resistance, maximum40
Contact resistance, maximum0.1
Control category to EN138493
Current, Utilisation category AC-153
Current, Utilisation category DC132
Degree of pollution to VDE 01102
EAN ( European Article Number)4030661323237
EAN (European Article Number)4030661323237
EMC rating10 V/m
Electrical power consumption, maximum5
Enclosure materialGlass-fibre reinforced thermoplastic, ventilated
FaultsFailure of the safety relay to pull-in or drop-out; Fault on the input circuits or the relay control circuits of the safety monitoring module; Interruption of the connections to the inductive proximity switches; Failure of the proximity switches; Failure of one channel being evaluated
Gross weight355.000
Height100
Input resistance at GND4000
Input signal, HIGH Signal "1"10 … 30 VDC
Input signal, LOW Signal "0"0 … 2 VDC
Integral System Diagnostics, status Yes
Material of the contacts, electricalAg-Ni 10 and 0.2 µm gold-plated
Mechanical life, minimum20000000
Mission Time20
MountingSnaps onto standard DIN rail to EN 60715
Net weight355.000
Note (Contact resistance)in new state
Note (Delivery capacity)Phased-out product
Note (General)Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Note (ISD -Faults)The following faults are registered by the safety monitoring modules and indicated by ISD.
Note (Wiring diagram)The wiring diagram is shown with guard doors closed and in de-energised condition.; The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix.; To monitor one guard door at plants with dangerous run-on movements up to PL d and Category 3; Standstill monitoring for unlocking solenoid interlocks; The solenoid interlock can be opened, when the fail-safe standstill monitor has detected the end of the run-on movement by means of two inductive proximity switches. When the button (E) is actuated, the coil of the solenoid interlock is energised.; For suitable IFL range p-type inductive proximity switches, refer to "Schmersal Catalogue Automatisierungstechnik".
Note (applications)safe standstill monitoring
Number of LEDs1
Number of auxiliary contacts1
Number of safety contacts4
Number of signalling outputs2
Number of undelayed semi-conductor outputs with signaling functi2
Overvoltage categoryIII
PFH-value0.0000001
Performance level, up tod
Product groupInitial
Product nameFWS 2505
Product type descriptionFWS 2505A
Protection class of Clips or TerminalsIP20
Protection class of the ClearanceIP54
Protection class of the enclosureIP40
Rated AC voltage for controls at DC minimum20.4
Rated AC voltage for controls, 50 Hz, minimum20.4
Rated AC voltage for controls, 60 Hz, minimum20.4
Rated control voltage at AC 50 Hz, maximum253
Rated control voltage at AC 60 Hz, maximum253
Rated control voltage at DC, maximum253
Rated impulse withstand voltage4.8
Rated operating voltage24 ... 230 VAC/DC
Reset after disconnection of supply voltage Yes
Resistance to vibrations to EN 60068-2-610 ... 55 Hz, Amplitude 0.35 mm
Restistance to shock30 g / 11 ms
Safety Integrity Level (SIL), applicable for2
StandardsIEC 61508
Storage and transport temperature, maximum70
Storage and transport temperature, minimum-25
Switching capacity, maximum250
Switching capacity, minimum10
Terminal ConnectorScrew connection; rigid or flexible
Terminal designationsIEC/EN 60947-1
Tightening torque of Clips0.6
Voltage, Utilisation category AC15230
Voltage, Utilisation category DC1324
Width45
Wire breakage detection Yes
eCl@ss number, Version 9.027-37-18-19

Housing

Weight355

mechanical data

depth121